4.4 Signal conditioning and readout circuits for MEMS/NEMS sensors
Citation:
MLA
Signal conditioning and readout circuits are crucial for MEMS/NEMS sensors. These systems amplify weak signals, filter out noise, and convert analog outputs to digital data. They're the bridge between tiny sensor movements and usable information.
Proper signal processing ensures accurate measurements from micro and nanoscale devices. It involves techniques like amplification, filtering, and temperature compensation to maximize sensor performance in real-world conditions.
Signal Conditioning
Amplification and Filtering
Amplification increases the strength of the sensor output signal to a level suitable for further processing
Involves using operational amplifiers (op-amps) configured as non-inverting or inverting amplifiers
Gain is determined by the ratio of feedback resistor to input resistor (A=1+RiRf)
Filtering removes unwanted frequency components from the amplified signal
Compensation methods include hardware techniques (temperature-sensitive elements, Wheatstone bridge) and software correction (lookup tables, polynomial fitting)
Example: A piezoresistive pressure sensor incorporates a temperature sensor and applies a correction factor based on the measured temperature
Readout Circuits
Bridge Circuits
Bridge circuits convert the change in sensor resistance or capacitance into a measurable voltage
Wheatstone bridge is commonly used for resistive sensors (strain gauges, piezoresistors)
Consists of four resistors arranged in a diamond configuration
Sensor resistance change causes an imbalance in the bridge, resulting in a differential output voltage
Capacitive bridge circuits measure the change in sensor capacitance
Employs a reference capacitor and a sensor capacitor in a balanced configuration
Capacitance change leads to a bridge imbalance, which is converted to a voltage signal
Bridge circuits offer high sensitivity, inherent temperature compensation, and rejection of common-mode noise
Example: A MEMS accelerometer uses a differential capacitive bridge to detect acceleration-induced displacement
Charge Amplifier and Lock-in Amplifier
Charge amplifier converts the charge generated by a piezoelectric sensor into a voltage signal
Utilizes an op-amp with a feedback capacitor to integrate the sensor charge
Output voltage is proportional to the input charge divided by the feedback capacitance (Vout=CfQin)
Provides low-noise amplification and high input impedance for piezoelectric sensors
Lock-in amplifier extracts weak sensor signals in the presence of significant noise
Employs phase-sensitive detection to isolate the signal of interest at a specific reference frequency
Multiplies the input signal with a reference signal and applies low-pass filtering to extract the DC component
Offers excellent noise rejection, high sensitivity, and the ability to measure small signals buried in noise
Example: A MEMS gyroscope uses a lock-in amplifier to detect the Coriolis force-induced vibration in a noisy environment
Data Acquisition
Analog-to-Digital Conversion and Multiplexing
Analog-to-digital conversion (ADC) translates the conditioned analog sensor signal into a digital representation
Sampling the analog signal at discrete time intervals (sampling frequency) and quantizing the amplitude into discrete levels (resolution)
Common ADC architectures include successive approximation, delta-sigma, and flash converters
ADC resolution (number of bits) and sampling rate (samples per second) determine the accuracy and bandwidth of the digitized signal
Multiplexing allows multiple sensor signals to share a single ADC
Analog multiplexer selects one sensor signal at a time to be digitized by the ADC
Reduces system cost and complexity by minimizing the number of ADCs required
Time-division multiplexing allocates a specific time slot for each sensor signal
Example: A multi-sensor MEMS system uses an analog multiplexer to sequentially sample temperature, pressure, and humidity sensors using a single ADC
Calibration
Calibration establishes the relationship between the sensor output and the corresponding physical quantity being measured
Involves applying known input stimuli to the sensor and recording the corresponding output values
Generates a calibration curve or lookup table that maps the sensor output to the measured quantity
Compensates for sensor nonlinearity, offset, and sensitivity variations
Field calibration is performed in the actual operating environment to account for external factors (temperature, humidity, pressure)
Calibration methods include single-point, two-point, and multi-point calibration
Single-point calibration adjusts the offset by comparing the sensor output to a known reference value
Two-point calibration corrects both offset and slope by using two reference points
Multi-point calibration captures the sensor response over a wide range of input values for higher accuracy
Example: A MEMS gas sensor is calibrated using known concentrations of the target gas to establish the relationship between the sensor resistance and gas concentration